John-wood Power Direct Vent (Non-ENERGY STAR qualified model User Manual Page 15

  • Download
  • Add to my manuals
  • Print
  • Page
    / 34
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 14
– 15 –
Before plugging in the water heater, always make sure:
The voltage and frequency correspond to that specified
on the water heater wiring diagram.
The electrical outlet has the proper overload fuse or
breaker protection.
Fill the tank with water and check all connections for
leaks. Open the nearest hot water faucet and let it run
for 3 minutes to purge the water lines of air and sedi-
ment and to ensure complete filling of the tank. The
electrical power may then be turned on. Verify proper
operation after servicing.
Note: Always reference the wiring diagram for the correct
electrical connections.
Resettable Lockout
The gas control/thermostat can be reset by unplugging the
power cord to remove power and then reinserting the plug
to restore the power. Robertshaw controls will automatically
attempt to reset after a 20 minute wait period. White-
Rodgers Intelli-Vent
TM
controls will automatically reset after
a 60 minute wait period. Also see "Troubleshooting Guide".
Figure 14 Wiring Diagram - White-Rodgers Control
Figure 13 Robertshaw Wiring Diagram - (Typical)
Page view 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 33 34

Comments to this Manuals

No comments