John-wood Commercial - AJWSC User Manual

Browse online or download User Manual for Water boiler John-wood Commercial - AJWSC. John Wood Commercial - AJWSC User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 29
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
COMMERCIAL GAS WATER HEATER
INSTALLATION AND OPERATING INSTRUCTIONS
for Signature Series models with prefix JWSC and AJWSC
Read and understand these instructions thoroughly before starting.
WARNING:
If the information in these instructions is
not followed exactly, a fire or explosion
may result causing property damage, per-
sonal injury or death.
WARNING:
Improper installation, adjustment, alter-
ation, service, or maintenance can cause
injury or property damage. Refer to this
manual. For assistance or additional infor-
mation, consult a qualified installer, serv-
ice agency, or the gas utility.
FOR YOUR SAFETY
Do not store or use gasoline or other
flammable vapours and liquids in the
vicinity of this or any other appliance.
Installation and service must be per-
formed by a qualified installer, service
agency or the gas utility.
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
Immediately call your gas supplier from
a neighbors phone. Follow the gas
suppliers instructions.
If you cannot reach your gas supplier,
call the fire department.
WHAT TO DO IF YOU SMELL GAS
PART NO. 64128 REV. A (07-05)
GSW Water Heating is a division of
A. O. Smith Enterprises Ltd.
Page view 0
1 2 3 4 5 6 ... 28 29

Summary of Contents

Page 1 - COMMERCIAL GAS WATER HEATER

COMMERCIAL GAS WATER HEATERINSTALLATION AND OPERATING INSTRUCTIONSfor Signature Series models with prefix JWSC and AJWSCRead and understand these inst

Page 2 - TABLE OF CONTENTS

Louvers and GrillsOpenings for air supply ducts must provide free unobstruct-ed air movement. Louver and grill openings must be sizedto ensure that th

Page 3

VentingIt is the responsibility of the installing contractor to provide avent adequate in capacity and in good usable condition.Btu/hr capacity limita

Page 4 - FLAMMABLE VAPOURS

WATER SUPPLYPiping InstallationPiping, fittings, and valves should be installed according tothe installation drawing (Figure 7). If the indoor install

Page 5

For example, a top inlet connection must use a top outletconnection.2. The installation of unions in both the hot and cold watersupply lines is recomm

Page 6

Important: Only a new temperature and pressure reliefvalve should be used with your water heater. Do not use anold or existing valve as it may be dama

Page 7 - GAS SUPPLY

Figure 11 Commercial Unit with Auxiliary Booster Heater - Two Temperature (With or Without Building Recirculation)Note: Install a vacuumrelief valve i

Page 8 - Gas Pressure

ELECTRICAL SUPPLYIf you lack the necessary skills required to properly installthe electrical wiring to this water heater, do not proceed buthave a qua

Page 9

INSTALLATION CHECKLIST– 17 –Check HereWater Heater Location1. Centrally located with the water piping system.Located as close to the gas piping and ve

Page 10 - Air Opening Requirements

IV) LIGHTING & OPERATING INSTRUCTIONS– 18 –WARNING: If you do not follow these instructionsexactly, a fire or explosion may result causing propert

Page 11 - (50 ft)

Safety Shut-offThis water heater is designed to automatically shut-off in theevent of the following:1. The pilot flame is extinguished for any reason.

Page 12 - Piping Installation

TABLE OF CONTENTSI) Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3User Responsibilities

Page 13

– 20 –Burner FlamesInspect the burner flames through the viewport and com-pare them to the drawings in Figure 15. A properly operat-ing burner should

Page 14

– 21 –Display Shows Display Showsno displayno displayno displayMain gas valve disconnectedPilot gas valve disconnectedSecondary disconnectLine disconn

Page 15 - Cold water supply

– 22 –Error modeWhen the integrated control detects a failure condition itenters Error mode. In this mode the display alternatesbetween showing “Err”

Page 16

– 23 –CALL FORHEAT ACTIVE(Temperature low)POWER INTERRUPTION Systemshuts offORPILOT FLAME FAILURE Valves close,after recycle delay system recycles. If

Page 17 - INSTALLATION CHECKLIST

Draining and FlushingIt is recommended that the tank be drained and flushedevery 6 months to remove sediment which may buildup dur-ing operation.Note:

Page 18 - Gas Control

8. Replace and sufficiently tighten the two screws holdingthe Pilot/Burner Assembly in place.9. Reconnect the gas supply line to the gas valve.10. Tur

Page 19 - Doing so can result in

– 26 –IX) TROUBLESHOOTING GUIDEDetect Conditions Alarm (ERROR) Name Control ActionService Suggestion (After Error Matured)Detection TimeRemote Display

Page 20 - 50 - 64mm (2 - 2 1/2 in.)

– 27 –Detect Conditions Alarm (ERROR) Name Control ActionService Suggestion (After Error Matured)Detection TimeRemote DisplayValve relays shorted/open

Page 21 - Operational status codes

– 28 –X) PARTS REFERENCE ILLUSTRATIONNo. Part Name and Description No. Part Name and Description1 Drafthood 14 Gas Valve2 Dip Tube (Top) 15 Main Burne

Page 22 - Installer mode

See Rating Label Serial Number prefix forWarranty Code. Reduced warranty periodapplies to Newfoundland.Warranty Code: P R S T U V W YStandard Warranty

Page 23

Thank you for purchasing a Commercial Water Heater.Properly installed and maintained, it will provide years oftrouble free service.This gas-fired wate

Page 24

This water heater is design-certified by CSA International asa Category I, non-direct vented water heater which takes itscombustion air either from th

Page 25 - VIII) COMBO HEATING

Safety Warning (Scalding)Hot water produced by this appliance can cause severeburns due to scalding. The hazard is increased for youngchildren, the ag

Page 26 - IX) TROUBLESHOOTING GUIDE

Unpacking the Water HeaterImportant: Do not remove any permanent instructions,labels, or the data label from outside of the water heater oron the insi

Page 27 - Table 6 (cont’d) Error Codes

• If the water heater is installed in a restaurant or food serv-ice location where the floor is cleaned frequently, NSFInternational requires the wate

Page 28

Note: If using a flexible gas connector, make sure its ratingtag matches or exceeds the input of the water heater.Tables 1, 2, and 3 provide a sizing

Page 29 - ~ Certificate of Warranty ~

Gas Leak TestingImportant: This water heater and its gas connection mustbe leak tested before placing the appliance in operation.• If the code require

Related models: Commercial - JWSC

Comments to this Manuals

No comments