Polaris
®
Residential Gas
Water Heater
Installation
Instructions and
Use & Care Guide
To obtain technical, warranty or service assistance during or
after the installation of this water heater, visit our website at:
http://www.gsw-wh.com
or call toll free:
1-888-479-8324
When calling for assistance, please have the following
information ready:
1. Model number
2. 7 Digit product number
3. Serial number
4. Date of installation
5. Place of Purchase
Table of Contents........................................................... 2
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch;
do not use any telephone in your
building.
Immediately call your gas supplier
from a neighbors telephone. Follow
the gas suppliers instructions.
If you cannot reach your gas
supplier, call the fire department.
Installation and service must be performed
by a qualified installer, service agency or
the gas supplier.
WARNING: If the information in these
instructions is not followed exactly, a fire
or explosion may result causing property
damage, personal injury or death.
322726-000
INSTALLER:
Affix these instructions to or adjacent to the water
heater.
OWNER:
Retain these instructions and warranty for future
reference. Retain the original receipt as proof of
purchase.
PRINTED IN U.S.A. 0112
This manual covers model numbers:
Canada
PR 100-34 2NV or 2PV
PR 130-34 2NV or 2PV
PR 130-50 2NV or 2PV
PR 150-34 2NV or 2PV
PR 150-50 2NV or 2PV
PR 175-50 3NV or 3PV
PR 199-50 3NV or 3PV
Note:
The manufacturer of this water heater recommends that it
be professionally installed by trained and qualified service
professionals.
Page view 0
1 2 3 4 5 6 ... 63 64

Summary of Contents

Page 1 - Use & Care Guide

1Polaris® Residential Gas Water HeaterInstallation Instructions and Use & Care GuideTo obtain technical, warranty or service assistance during or

Page 2 - Important Instructions

10INLET/OUTLET VENT TERMINATIONSStandard Horizontal TerminationWhen 3 inch pipe is used between the water heater and the outside wall, reduce it to 2

Page 3 - Unpacking the Water Heater

11VERTICAL TERMINATIONSWhen 3 inch pipe is used between the water heater and the roof, reduce it to 2 inch pipe before penetrating the roof. A maximum

Page 4 - Location Requirements

12CONCENTRIC VENT TERMINATIONSFor new installations, install 2” or 3” ULC S636 certified PVC or CPVC concentric vent terminations may be used. See the

Page 5 - CONDENSATE LINE

13Figure 14: Input GraphGas Input RateThe gas input rate of this water heater is affected by several environmental factors such as:• The heating valu

Page 6 - VENT PIPE SYSTEM

14Figure 15: Typical One-Temperature System Piping InstallationMixing Valve InstallationA mixing valve has been provided for use with the Polaris® Ga

Page 7 - Preventive Maintenance

15• Do not use with piping that has been treated with chromates, boiler seal or other chemicals and do not add any chemicals to the water heater pipi

Page 8 - Vent Pipe Length

16Temperature and Pressure Relief ValveFor protection against excessive pressures and tempera-tures, a temperature and pressure relief valve must be i

Page 9 - Vent Termination Locations

17GAS SUPPLY AND PIPINGGas RequirementsRead the data plate to be sure the water heater is made for the type of gas being used. This information will

Page 10 - (30.5 cm)

18Gas Pressure TestingImportant: This water heater and its gas connection must be leak tested before placing the appliance in operation. • If the co

Page 11 - VERTICAL TERMINATIONS

19Electrical Shock HazardDisconnect power beforeservicing.Replace all parts and panelsbefore operating.Failure to do so can result in death or electri

Page 12 - CONCENTRIC VENT TERMINATIONS

2Your safety and the safety of others are very important.We have provided many important safety messages in this manual and on your appliance. Always

Page 13 - WATER PIPING SYSTEM

20WIRING DIAGRAMHEATER SUPPLIED WITH T92 SERIES RELAYHEATER SUPPLIED WITH KUHP SERIES RELAYNOTICE: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE A

Page 14 - General Information

21INSTALLATION CHECKLISTWater Heater Location Requirements Centrally located with the water piping system. Located as close to the gas piping and ve

Page 15 - Adequate Drain

22OPERATING YOUR WATER HEATERRead and understand these directions thoroughly before attempting to operate the water heater (see Operating Instructions

Page 16 - Relief Valve

23occurrence of igniter failure due to excessive condensate.Important: A mixing valve (provided) must be installed in the hot water outlet to reduce

Page 17 - Minimum

24OPERATIONAL CONDITIONSMAINTENANCEWater Heater SoundsDuring the normal operation of the water heater, sounds or noises may be heard. These noises are

Page 18 - Gas Pressure Testing

25MAINTENANCE OF YOUR WATER HEATER3 Month InspectionAt least every 3 months, a visual inspection should be made of the combustion air inlet as well as

Page 19 - ELECTRICAL CONNECTIONS

26TROUBLESHOOTINGTable 5:Ignition Control Module (ICM) LED Error Codes: (Flashes visible through viewport in access door)FLASHES INDICATED PROBLEM CON

Page 20 - WIRING DIAGRAM

27SOFTWARE OPERATION SEQUENCEIGNITION CONTROL MODULE SOFTWARE OPERATION SEQUENCE

Page 21 - Concentric

28REPAIR PARTS LIST/DIAGRAMITEMNO.PARTS DESCRIPTION1 1” NPT x 2.5” BRASS NIPPLE2 THERMOSTAT SENSOR BUSHING3 O-RING4 THERMOSTAT SENSOR/ECO5 INVERTED FL

Page 22 - OPERATING YOUR WATER HEATER

29POLARIS MODELS & DIMENSIONSFigure 26MODEL NUMBERGAL.(Liter) CAP.INPUT MBTU PER HR.(Kilowatt)VENT DIA.INCHES EXTERIORWATER CONNECTIONST&P HGT

Page 23 - and may vary

3INSTALLATION INSTRUCTIONSConsumer InformationOBSERVE ALL GOVERNING CODES AND ORDINANCES.This water heater is design-certified by CSA International as

Page 26 - TROUBLESHOOTING

32Copyright © 2011 GSW Water Heating is a division of A.O.Smith Enterprises Ltd. All Rights ReservedShould you have any questions on obtaining technic

Page 27 - SOFTWARE OPERATION SEQUENCE

32Droits d’auteurs© 2011 GSW Water Heating est une division de A.O.Smith Enterprises Ltd. Tous droits réservésSi vous avez des questions concernant l

Page 30

29MODÈLES ET DIMENSIONS POLARISArrivée d’airCÔTÉ GAUCHE AVANT HAUTAlimentation en gazSoupape DSTBouton de réglage de températureEntrée d’eau froideSor

Page 31

28LISTE/DIAGRAMME DES PIÈCES DE RECHANGENo d’articleDESCRIPTION DE LA PIÈCE1 MAMELON LAITON 1 PO NPT X 2,5 PO 2 MANCHON DU CAPTEUR DU THERMOSTAT 3 JOI

Page 32 - Residential Gas Water Heater

27SÉQUENCE DE FONCTIONNEMENT DU LOGICIEL SÉQUENCE DE FONCTIONNEMENT DU LOGICIEL DU MODULE DE LA COMMANDE D’ALLUMAGEOUIOUIOUIOUIOUIOUIOUIOUIOUINONNONOU

Page 33

26DÉPANNAGETable 5 :Codes d’erreur DEL du Module de commande d’allumage (ICM) : (Les clignotements sont visibles à travers la clôture située dans la p

Page 34 - REMARQUES

4Location RequirementsThe water heater design has been tested by CSA International and complies with ANSI Z21.10.1, Section 2.35 Flammable Vapors Resi

Page 35

25ENTRETIEN DU CHAUFFE-EAUInspection après 3 moisAu moins une fois chaque 3 mois une inspection visuelle devrait être faite de l’arrivée d’air de comb

Page 36 - MODÈLES ET DIMENSIONS POLARIS

24CONDITIONS OPÉRATIONNELLESENTRETIENChauffe-eau bruyantLe fonctionnement normal du chauffe-eau est accompagné de bruits ou de sons qui sont courants

Page 37 - Liste des pièces de

23température plus élevée que 130°F (54,4°C) peut réduire la survenue d’une défaillance de l’allumeur en raison d’un surplus de condensat. Important :

Page 38 - D’ALLUMAGE

22FONCTIONNEMENT DU CHAUFFE-EAULire et comprendre ces directions dans leur intégralité avant de tenter de faire fonctionner le chauffe-eau (voir la No

Page 39 - DÉPANNAGE

21LISTE DE CONTRÔLE RELATIVE À L’INSTALLATIONExigences en matière d’emplacement du chauffe-eau Emplacement central par rapport à la tuyauterie d’eau

Page 40 - Figure 25

20SCHÉMA DE CÂBLAGECHAUFFE-EAU FOURNI AVEC UN RELAIS DES SÉRIES T92AVIS : SI L’UN DES FILS D’ORIGINE, TEL QUE CELUI FOURNI AVEC L’APPAREIL, DOIT ÊTRE

Page 41 - Vidange et rinçage

19Risque de choc électriqueCouper l’alimentation électrique avant toute réparation.Replacer toutes les pièces et les panneaux avant de mettre en march

Page 42 - AVERTISSEMENT

18Essai de pression du gazImportant : Il est impératif de vérifier l’étanchéité du chauffe-eau et des raccords de gaz avant de mettre l’appareil en ma

Page 43 - FONCTIONNEMENT DU CHAUFFE-EAU

17ALIMENTATION EN GAZ ET TUYAUTERIE DE GAZExigences relatives au gazLire la plaque signalétique pour s’assurer que le chauffe-eau est conçu pour le ty

Page 44 - Concentrique

16Soupape de décharge à sécurité thermiquePour assurer la protection contre la surpression et la surchauffe, une soupape de décharge à sécurité thermi

Page 45 - SCHÉMA DE CÂBLAGE

5CONDENSATE LINEImportant: Do not run the condensate drain in areas that are likely to freeze. Frozen condensate will block the drain line and result

Page 46

15• Ne pas l’utiliser avec une tuyauterie qui a été traitée avec des chromates, joints de chaudière ou autres produits chimiques et n’ajouter aucun p

Page 47

14Figure 15 : Installation type de tuyauterie à système à une températureInstallation du mélangeurUn mélangeur a été fourni afin qu’il soit utilisé av

Page 48

13Longueur de ventilationEntrée en Btu/h150 000 BUT/Hr (44 kW)130 000 BUT/Hr (38 kW)100 000 BUT/Hr (29 kW)Figure 14 : Graphique de productionTaux de p

Page 49

12TERMINAISONS DE VENTILATION CONCENTRIQUESPour les nouvelles installations, on peut utiliser les terminaisons de ventilation concentrique en PVC ou C

Page 50 - Système de chauffage solaire

11TERMINAISONS VERTICALES Lorsqu’un tuyau de 3 po est utilisé entre le chauffe-eau et le toit, le réduire à 2 po avant de le faire pénétrer dans le to

Page 51

10TERMINAISONS DE VENTILATION D’ENTRÉE/SORTIETerminaison horizontale standard Lorsqu’un tuyau de 3 po est utilisé entre le chauffe-eau et le mur extér

Page 52 - RÉSEAU DE CONDUITE D’EAU

9Emplacements de la terminaison de ventilationL’arrivée d’air et la sortie d’évacuation doivent être installé avec les dégagements minimums suivants (

Page 53 - Figure 13E, 13F, 13G

8Matériau du tuyau de ventilationTuyauterie d’arrivée d’air de combustion; Les matériaux en plastique suivants peuvent être utilisés pour la tuyauteri

Page 54 - TERMINAISONS VERTICALES

7Installation du filtre intégré Lors de l’installation de le manchon en caoutchouc de l’adaptateur, noter les points suivants :• Enlever et jeter le

Page 55 - 30 cm (12 po)

6Conduit de vidange de condensatToutes les pièces du purgeur de condensat sont collées à l’exception du joint de tige de vidange en CPVC de 1/2 po au

Page 56 - Entrée de

6Condensate Drain LineAll parts of the condensate trap are glued except for the 1/2” CPVC drain stem joint at the elbow (see figure 3A). This assembl

Page 57 - Longueur du tuyau de

5TUYAU DE CONDENSATImportant : Ne pas acheminer les conduites des condensats dans des zones susceptibles de geler. Un condensat gelé bloquera la condu

Page 58 - Entretien préventif

4Exigences relatives à l’emplacementLa conception du chauffe-eau a été testée par CSA International et elle est conforme avec ANSI Z21.10.1, Section 2

Page 59

3INSTRUCTIONS D’INSTALLATIONRenseignements destinés à l’acheteurOBSERVER L’ENSEMBLE DES CODES ET ORDONNANCES APPLICABLES.Ce chauffe-eau présente une c

Page 60 - TUYAU DE CONDENSAT

2Il est très important de veiller à sa propre sécurité et à celles des autres.De nombreux messages et consignes de sécurité sont indiqués dans le manu

Page 61 - INFLAMMABLES

1Chauffe-eau résidentiel au gaz Polaris®Instructions d’installation et guide d’utilisation et d’entretienPour obtenir une assistance technique et des

Page 62

7Integrated Filter InstallationWhen installing the adaptor rubber boot, note the following:• Remove and discard the plastic cap from the outer clamsh

Page 63

8Vent Pipe MaterialCombustion Air Inlet Piping; The following plastic materials may be used for combustion air inlet piping. IMPORTANT: Follow all loc

Page 64 - Instructions

9Vent Termination LocationsThe air inlet and exhaust outlet must be installed with the following minimum clearances (see figure 6):• Twelve inches (3

Comments to this Manuals

No comments