Check the Gas
Check that the rating plate indicates the correct type of gas.
Check that the gas supply line is sized
for 194,000 Btuh for this unit.
Check the Power
The power supply required is 120V AC,
at 60Hz. Using the incorrect voltage
may result in fire or electric shock.
Do Not Use Equipment for Purposes Other Than Those Specified
Do not use for purposes other than increasing the temperature of the water supply,
as unexpected accidents may occur as a result.
Check Water Supply Quality
If the water supply is hard, acidic or otherwise impure, treat the water with approved methods in
order to ensure full warranty coverage.
Use Extreme Caution if Using With A Solar Pre-Heater
Using this unit with a solar pre-heater can lead to unpredictable output temperatures and
possibly scalding. If absolutely necessary, use mixing valves to ensure output temperatures do
not get to scalding levels. Do not use a solar pre-heater with the quick-connect multi-system.
Checkup
Check the fixing brackets and vent pipe yearly for damage or wear. Replace if necessary.
4.
Before Installation
Caution
Precautions on Vent Pipe Replacement
The vent system will almost certainly need to be replaced when this appliance is being installed.
Use vent pipe that is listed to UL 1738 for Category III appliances for the exhaust venting. Category
III listed vent pipe is suggested for the air supply pipe also, but other materials may be acceptable.
Consult local codes.
* If Category III listed vent pipe is already installed, check for punctures, cracks or blockages and
consult with the vent pipe manufacturer before reusing.
Use Approved Vent Materials
Use only vent materials that are listed to UL 1738 for Category III appliances for the exhaust venting
of this appliance.
Improper venting may result in fires, property damage or exposure to Carbon Monoxide.
Snow Precaution
If this product will be installed in an area where snow is known to accumulate, protect the vent
termination from blockage by snow drifts or damage from snow falling off of roofs.