The pipe cover protects the plumbing pipes to
the waterheater from unexpected adjustments.
Thispipecoverisfixedtothebottomofthewater
heater, which hides the plumbing and improves
thevisualaspectsofthewholeinstallationforthe
waterheater.
5. 3" ULC S636 PVC Concentric Termination: TH-CVPVC33
Used when terminating direct-vent (sealed-combustion)
systems,withdirect-ventmodelsthatrequirea76mm(3
in.)intakeanda76mm(3in.)exhaust.Thisconcentric
termination provides the convenience of only having to
makeonepenetrationthroughasidewallinsteadoftwo
separate penetrations for the intake and exhaust piping.
The termination includes a bird screen, restricting small
animals, pests, and foreign objects from entering into the
vent system.
NOTE: Concentric (single penetration) terminations are
only permitted for sidewall (horizontal) terminations.
Roof (vertical) terminations must use two separate
penetrations.
Installaon
Installaon Manual
The temperature remote controller has two
functions.Itallowstheoutputtemperaturefrom
thewaterheatertobeadjustedwithintherange
of 38 °C to 85 °C,anditalsoworksasadiagnostic
toolthatwillgiveaconciseerrorcodewhenever
thereisaproblemwiththeunit.Thetemperature
options are 38 °C (100 °F), 40 °C (105 °F), 43 °C
(110°F), 45 °C(115°F), 50 °C(120°F), 52 °C(125
°F), 55 °C(130°F), 57 °C(135°F), 60 °C(140°F), 63
°C(145°F), 65 °C(150°F), 68 °C(155°F), 70 °C(160
°F), 75 °C(165°F), 80 °C(175°F) and 85 °C(185°F).
See the troubleshooting section for information
on possible error codes.
1. Temperature remote controller:
TM-RE40
2. Backflow Preventer: TK-BF01
Thebackflowpreventerpreventsthebackflow
of air through the exhaust vent. This helps
prevent harmful exhaust gases from entering
the home, as well as helping to prevent the
unit fromfreezingin areaswherecoldair can
be blown or drawn into the exhaust system.
Install this vent damper in accordance with
the installation instructions and any applicable
codes.
3. Pipe covers: TH-PC03
4. Neutralizer kit: TH-NT01
The neutralizer assembly
neutralizes the condensate
(acidicwater)thatformsinthe
secondary heat exchanger of
thewaterheater.
It connects to the condensate
drain port of the water heater
by using connectors included
with the neutralizer kit. Refer
to p. 24 for the details.