391
TwoTimes Air-fuel ratio rod
failure
• Checkforconnection/breakageofwires(Part#709)
and/orsootontheAFRrod.(Part#108)
441
TwoTimes Flowsensorfailure
(Easy-LinkSystemonly)
• Check for connection/breakage of wires and/or
debrisontheflowsensorimpeller.(Part#402)
510
Six Times Abnormal main gas
solenoid valve
• Check for connection/breakage of wires (Part #708)
and/orburnmarksonthecomputerboard(Part#701).
551
Six Times Abnormal gas
solenoid valve
• Check for connection/breakage of wires (Part #708)
and/orburnmarksonthecomputerboard(Part#701).
611
Four Times Fan motor fault • Checkforconnection/breakageofwires,dustbuildup
inthe fanmotor(Part#103)and/orburnmarkson
thecomputerboard(Part#701).
• Checkforfrozen/corrosionofconnectors(Part#103).
651
Four Times Flowadjustment
valvefault(Easy-
LinkSystemonly)
• Inspect the flow adjustment valve (Part #402), for
connection/breakage of wires, locked motor drive
duetoscalebuildup,and/orwaterleakage.
661
Four Times Bypassvalvefault
(T-H3-DV/540H
only)
• Inspectthebypassvalve(Part#403),forconnection/
breakage of wires, locked motor drive due toscale
buildup,and/orwaterleakage.
701
One Time Computer board
fault
• Checkforconnection/breakageofwires(Part#714).
711
One Time Gas solenoid valve
drive circuit failure
• Referto111and121errorcode.
721
Six Times False flame
detection
• For indoor models, check if condensate drain is
installedontheventcollarofthewaterheater.
• Checkifthereisleakingfromheatexchanger(Part#401).
741
N/A Miscommunication
betweenwater
heater and remote
controller
• Check the model type of the remote controller.
• Inspect the connections between the water heater
and remote controller.
• Checkthepowersupplyofthewaterheater.
751
N/A Miscommunication
betweenwater
heater and
temperature
controller
• Inspect the connections between the water heater
and temperature controller.
• Checkthepowersupplyofthewaterheater.
761
N/A Miscommunication
in Easy-Link system
• Check if the connections between the parent unit
andthechildunitsarecorrect.Refertop.26-29.
941
Five Times Abnormal exhaust
temperature
• Check if the set temperature is higher than 60 °C
(140°F)andthesystemisRecirculation.
991
Five Times Imperfect
combustion
• Checkthegastypeofthewaterheater.
• Inspect the environment around the water heater.
Determinehowlongtheunithasbeeninstalled.
• Check the altitude/elevation of the area of where
thewaterheaterisinstalled.
• Check if there is any blockage in the intake air and/
or exhaust.
• Ifthewaterheaterisinstalledasadirect-ventsystem,
checkwhetherthereisenoughdistancebetweenthe
intake air terminal and the exhaust terminal.
• Checkifthereisgreaseand/ordirtintheburner(Part
#101)andthefanmotor(Part#103),especiallyifthe
water heater has been installed in a contaminated
area.