19 Page
-For sidewall terminaons-
-For rooop terminaons-
Formultiplesidewallexhaustterminations(e.g.multi-unit
systems),anexhaustterminationmustbeatleast305mm
(1ft.)awayfromanotherexhausttermination.Anexhaust
termination must also be at least 610 mm (2 ft.) away
fromaninsidecorner.(iftheadjacentwallislessthan610
mm(2ft.)oflength,theminimumrequireddistanceaway
fromtheinsidecornerwillbeequaltothelengthofthat
adjacentwall.)
For multiple-unit, direct-vent sidewall terminations that
combine the intake and exhaust into a single penetration,
spaceeachdirect-ventterminationatleast305mm(1ft.)
awayfromeachother,nomattertheorientation.Adirect-
ventterminationmustalsobeatleast610mm(2ft.)away
fromaninsidecorner.(iftheadjacentwallislessthan610
mm(2ft.)oflength,theminimumrequireddistanceaway
fromtheinsidecornerwillbeequaltothelengthofthat
adjacentwall.)
For multiple-unit rooftop terminations (whether for standard or direct-vent installations) space all
exhaustandintaketerminationsinaccordancewithlocalcodes.Anexhaustterminationmustbespaced
fromawallorsurfaceinaccordancewithlocalcodesaswell.Intheabsenceofsuchacode,anexhaust
terminationmustbeahorizontaldistanceofatleast610mm(2ft.)awayfromawallorsurface.
Exhaust and/or
direct-vent sidewall
terminations should
be at least 610 mm
(2 ft.) away from an
opposite surface/
wall.Donotplacethe
termination directly
in front of an opening
into a building
.
610 mm
(2ft.)
Exhaust
termination
Please follow all local and national codes in regards to proper termination
clearances. In the absence of such codes, the above clearances can be used as
guidelines. Local codes supersede these guidelines.
CAUTION
Installaon
Exhaust
termination
Inside
corner
305 mm
(1ft.)
610 mm
(2ft.)
305 mm
(1ft.)
Installaon Manual
A:Inaccordancewithlocalcodes
Air intake
A
Exhaustterminaon
A
A
A
A
Air intake
610 mm
(2)
Exhaust
terminaon
For direct-vent sidewall
terminationsthatusetwo
separate penetrations for
the intake and exhaust,
distance the intake and
exhaust terminations at
least915mm(3ft.)away
from each other, no
matter the orientation.
915
mm
(3ft.)
Air supply inlet
915 mm
(3ft.)
915 mm
(3ft.)
Exhaust
termination
Combined
intake and
exhaust
termination
Inside
corner
305 mm
(1ft.)
610 mm
(2ft.)
305 mm
(1ft.)